Milwaukee MC810US MAX pH/TDS/Temp Monitor

SKU:
MC810US
UPC:
810666004223
MPN:
MC810US
Range:
0.0 - 12.0 pH | 0 to 1990 ppm | 14.0°F to 140.0°F
Resolution:
0.1 pH | 10 ppm | 0.1°F / 0.1°C
Accuracy:
± 0.2 ph | ± 2% Full Scale | ±0.5°F (±0.3°C)
Calibration:
pH Manual, 2 Point (trimmer) | TDS, Manual 1 point | Temp. Factory Calibrated
Manual:
Milwaukee MC810 Manual

Options

$257.90
Or

Info

SKU:MC810US ,UPC:

Info

SKU:
MC810US
UPC:
810666004223
MPN:
MC810US
Range:
0.0 - 12.0 pH | 0 to 1990 ppm | 14.0°F to 140.0°F
Resolution:
0.1 pH | 10 ppm | 0.1°F / 0.1°C
Accuracy:
± 0.2 ph | ± 2% Full Scale | ±0.5°F (±0.3°C)
Calibration:
pH Manual, 2 Point (trimmer) | TDS, Manual 1 point | Temp. Factory Calibrated
Manual:
Milwaukee MC810 Manual

Warranty

Specifications pH Range: 0.0 - 12.0 pH pH Resolution: 0.1 pH pH Accuracy: &pl…

Warranty

Specifications


pH Range: 0.0 - 12.0 pH
pH Resolution: 0.1 pH
pH Accuracy: ±0.2 pH
pH Calibration: Manual, 2 points (trimmer)
pH Probe: MA911B/2 (included)
TDS Range: 0 - 1990 ppm
TDS Resolution: 10 ppm
TDS Accuracy: ±2% Full Scale
TDS Calibration: manual, 1 point (trimmer)
TDS Probe: MA811 (fixed, Included)
Temperature Range: 14.0 to 140.0 °F (-10.0 to 60.0 °C)
Temperature Resolution: 0.1 °F / 0.1 °C
Temperature Accuracy: ±0.5 °F / ±0.3 °C
Temperature Calibration: Factory Calibrated
Temperature Compensation: Automatic, 41 to 122 °F (5 to 50 °C), (TDS / EC Readings Only)
Temperature Probe: Stainless Steel (fixed, included)
Power Supply: 12 VDC adapter (included)
Dimensions: 6.3" x 4.3" x 1.4" (160 mm x 110 mm x 35 mm )
Weight: 1.2 lbs. (560 g)

Description

Accurate. Simple. Reliable. 24/7 pH/TDS/Temp Monitoring.

Why Guard when you can Monitor! The Milwaukee MC810 MAX pH/TDS/Temp Monitor lets you monitor your pH/TDS/Temp levels 24/7 automatically.

Comments From Field Testing

"I run this unit 24/7 and have not had any problems for the past two months. I can monitor 24/7, point a camera on it and connect to my phone."

"Easy to calibrate."

"Using this now, far less expensive than what my friends paid ... I recommend this to any serious grower."

Summary

The Milwaukee MC810 MAX pH/TDS/Temperature Monitor is preferred by people looking to continuously track pH and nutrient levels 24/7. Quick to setup and simple to use, this monitor offers simultaneous display of all three main parameters on 3 large, backlit LCD readouts.

Common uses are nutrient tanks, Hydroponics and aquariums. The MC810 MAX comes with a complete mounting kit including a probe holder.

Features

Accuracy

The Milwaukee MAX Monitor offers an accuracy to ± 0.2 pH with two point manual calibration, TDS accuracy of ±2% Full Scale and ±0.5 °F (0.3C) temperature accuracy.

Automation

Just calibrate the parameters and begin to monitor 24/7!

Easy installation

The MC811 MAX pH/EC/Temp Monitor comes with with two complete probe mounting kits.

Design features

  • Fast, easy-to-read current results with 3 large digital backlit LCD readouts.
  • External Switch atop the unit converts EC conductivity to TDS (ppm) using 0.5 or 0.7 conversion factor
  • Simple two-point pH calibration  and one-point TDS, for increased accuracy with manual trimmers for easy adjustment
  • Gel-filled, double junction, lab grade pH electrode for low maintenance and high performance
  • Low maintenance fixed TDS probe
  • 6.5’ probe cables for extra flexibility when testing
  • 12 VDC power supply
  • Compact size of only 6.3” x 4.3” x 1.4”
  • Weighs only 1.2 lbs

 

Use and Care 

pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

Sensing bulb

The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

Reference junction

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

You can extend the life of your pH electrode in the following ways.

Storage

The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Store the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

Cleaning

Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

Calibration

The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your MAX pMonitor accurate. Also, calibrate after cleaning or a long period of storage.